The U3600-QAL1 is an ideal particulate monitor for applications, including combustion, incineration, metals, minerals, and various industrial processes.
With certifications from TUV and UK MCERTS, it is certified to meet the latest EN14181 standards and US MACT rules. Typically positioned after dust collector baghouses and cartridge filters, the U3600-QAL1 is currently certified to Air Quality standard EN 15267-1 (QAL1) by both TUV and MCERTS, with improved functionality over the original TRIBO.dsp U3600.
Features
- Complies with EN14181, EN13284-2, and EN 15267-3 requirements
- Certified range of 0-15 mg/m3 , measuring range 0-1,000 mg/m3
- Measures Pico Amps (pA) directly so can be immediately used as a qualitative monitor without the need for Iso-Kinetic calibration*
*A direct measurement of pAmps allows the instrument to be used as a qualitative device “out of the box” (e.g. for European regulation EN15859). In order to meet European regulation EN15267-2, calibration to an Iso-Kinetic test is required where calibrations to a linear or curved coefficient can be directly set within the 3600QAL1 controller fascilitating more accurate correlations to actual dust and thereby making the instrument more reliable. (Features typically not available from other Charge transfer technologies.)
Applications for the U3600-QAL1
- Emissions Monitoring
- Bag leak detection
- Dust collector maintenance
- Product loss prevention
- Equipment protection
- EPA/MACT Compliance.
- Process Monitoring
-
- Process optimization
- Gravity feed
- Injection flow
- Material flow
- Flow/no flow detection.
-