Model 4030 Total Hydrocarbon Analyzer

The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.

Series 4000 Overview

All 4000 series units employ the same basic architecture and electronics; however, each analyzer has additional features:

​4020 Total Hydrocarbon Analyzer Uses FID to measure total hydrocarbons in ppm in a sample gas stream
​4030 Total Hydrocarbon Analyzer Basic 40​​20 with sample system at a higher temperature for heated applications
Avoids condensation of the sample
4040 Methane / Non-Methane Basic 4020, plus temperature-controlled sampling system with GC column to give accurate readings of both methane and non-methane hydrocarbons in a gas stream
4060 Benzene Analyzer Same as 4040, but used to measure ppb levels of benzene instead of methane/non-methane
​4080 Total Hydrocarbon Analyzer Basic 4020 with sample system including stripper to measure total hydrocarbons in an aqueous sample

 

Series 4000 Hydrocarbon Analysers range brochure

Brand

Laboratory & Scientific

Stack, Process & CEMS

Features

  • Easy to use software, user programmable ranges
  • GC technology used for complete separation of Methane, Ethylene Oxide, Benzene, Styrene, BTX and many other compounds (application dependent)
  • Automatic fuel shut off system
  • Electronic flame-out guard circuit
  • Adjustable alarm and oven settings
  • Fast response
  • Sample filter with exchangeable stainless steel element
  • Built-in sample pump (optional)
  • Stainless steel sample system with flexible design to handle either a 100% H2, H2/N2 or H2/He support gas fuel mixture
  • Automatic ignition
  • X-purged configuration for hazardous area installations available
  • Standard auto-calibration programming, ideal for unmanned plant conditions
  • Enhanced temperature control of sample compartment for stable, reproducible results
  • Easily accessible pressure and flow control devices
  • Slide out chassis design for easy access to internal components
  • CE marked
  • Optional methanizer for CO and CO2 measurements

Applications

  • Ambient monitoring of THC
  • THC​​ measurement of automotive exhaust

Specifications

Ranges 0-10, 0-100, 0-1000 ppm THC. Other ranges available
Sensitivity 1% of FS
Resolution 0.1 ppm
Accuracy ± 2% of FS at constant temperature
Response Time 90% in less than 15 seconds, data updated every 5 minutes
Temperature 40° to 110° (4.44° to 43.33°C)
Fuel UHP Hydrogen @ 30 PSI incoming pressure (standard)
Power 115 or 220 VAC, 50/60Hz, 600VA
Noise Less than 0.5% of FS
Drift 2% FS per week
Linearity 1% FS through all ranges
Repeatability 1% FS through all ranges
​Sample Chamber 212° to 248°F (100° to 120°C) per application
​Flow Rate 1 Liter/minute (standard)
Outputs 0-1 VDC & 4-20 mADC, isolated current output
Warm-Up Time Usable in approximately 4 hours
Stable in approximately 8 hours
Carrier Gas UHP Nitrogen @ 50 PSI incoming pressure
Enclosure 19″ rack mounted steel enclosure
19″W x 8.75″H x 15.5″D
(48.3 x 22.2 x 39.4 cm)