LaserTrace 2.5 O2

Delivering your best measurement

Detect gas quality upsets before they can damage your processes. Using Tiger Optics’ LaserTrace 2.5 O2 analyzer, you can verify oxygen impurity levels with part-per-trillion accuracy, drift-free stability, and virtually immediate response. You’ll find our system exceptionally easy and fast to install, and effortless to maintain, with built-in zero verification. It measures in bulk gases, specialty gases, and gas mixtures. And its robust design—free of moving parts—results in an analyzer that has a high Mean Time Between Failure (MTBF) rate and a very low Cost of Ownership (CoO).

Designed for trace level contamination analysis, the LaserTrace 2.5 O2 offers:

  • Industry-leading parts-per-trillion detection capability
  • Unprecedented speed of response
  • Widest available dynamic range
  • Absolute measurement (freedom from calibration gases)
  • Flexibility: up to four (4) measurement points per electronics module
  • Extremely low cost of ownership
  • Electronics module compatible with existing LaserTrace sensor modules

Applications

  • Gas Quality Control
  • Gaseous CRMs & Calibration Gas Mixtures
  • High-Purity Gases & Systems
  • Research & Development

Learn More

Brand

Laboratory & Scientific

Stack, Process & CEMS

Detection Capability

Detection and Matrix Range LDL (3σ) Precision (1σ) @ zero
O2 in N2 0 – 2.5 ppm 200 ppt 70 ppt
O2 in He 0 – 0.5 ppm 50 ppt 20 ppt
O2 in Ar 0 – 1 ppm 90 ppt 45 ppt
O2 in H2 0 – 2 ppm 150 ppt 50 ppt
O2 in CO2§ 0 – 5 ppm 5000 ppt 150 ppt
§Special configuration required,
must be specified at time of order.

Specifications

Performance
Operating range See Detection Capability table
Detection limit (LDL, 3σ/24h) See Detection Capability table
Precision (1σ, greater of) ± 0.75% or 1/3 of LDL
Accuracy (greater of) ± 4% or LDL
Speed of response < 3 minutes to 95%
Environmental conditions 10°C to 40°C, 30% to 80% RH (non-condensing)
Storage temperature -10°C to 50°C
Gas Handling System and Conditions
Wetted materials 316L stainless steel (optional corrosion-resistant material), 10 Ra surface finish
Gas connections 1/4” male VCR inlet and outlet
Leak tested to 1 x 10-9 mbar l / sec
Sample inlet pressure 10 − 125 psig (1.7 − 9.6 bara)
Flow rate 0.5 – 1.8 slpm (gas dependent)
Sample gases Most inert, toxic and passive matrices
Gas temperature Up to 60°C
Dimensions, H x W x D
Electronics unit 14″ x 19″ x 14″ (356 mm x 483 mm x 356 mm)
O2 sensor (rackmount only) 8.75″ x 19″ x 27″ (222 mm x 483 mm x 686 mm)
Sensor rack
(fits 1 H2O and 1 O2 sensor)
8.75″ x 19″ x 27″ (222 mm x 483 mm x 686 mm)
Weight
Electronics unit 32 lbs (14.5 kg)
O2 sensor 60.5 lbs (27.5 kg)
Electrical
Alarm indicators User programmable setpoints (1 per sensor), Form C relays
Power requirements 90 − 240 VAC, 50/60 Hz
Power consumption 200 Watts max.
Signal output Isolated 4−20 mA per sensor
User interfaces 10.4” LCD touchscreen, PS/2 for mouse and keyboard
10/100 Base-T Ethernet, 2 USB ports, RS-232
Patents
U.S. Patent # 7,277,177 • U.S. Patent # 7,255,836

Request information or pricing

If you need a quote, specifications or technical info, or anything else – please submit the form below and one of our team of experts will happily get back to you within 24 business hours. 

  • This field is for validation purposes and should be left unchanged.

Related Products